      Frequency converter
FC-202P90KT4E21H1TGCXXXSXXXXALB2CXXXXD0
VLT® AQUA Drive FC-202
(P90K) 90 KW / 125 HP, Three phase
380 - 480 VAC, IP21 / Type 1
(H1) RFI Class A1/B (C1)
Safe Stop
Graphical Loc. Cont. Panel
Coated PCB, No Mains Option
Latest release std. SW.
PROFINET MCA 120, MCB-112 PTC Therm. Card
No C1 option, MCB-107 24V DC backup
Frame: C2
Other options according to Model code
Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful sta.
| Gross weight | 60.5 kg | 
| Net weight | 60.2 kg | 
| Volume | 228.095 l | 
| EAN | 5715253331348 | 
| Product View (Switch) | GLBL | Global (Standard) | 
| Product Group | FC- | VLT® AQUA Drive FC- | 
| Series | 202 | 202 | 
| Power Rating | P90K | (P90K) 90 KW / 125 HP | 
| Phase | T | Three phase | 
| Mains Voltage | 4 | 380 - 480 VAC | 
| Enclosure | E21 | IP21 / Type 1 | 
| RFI Filter | H1 | (H1) RFI Class A1/B (C1) | 
| Brake - Safe Stop | T | Safe Stop | 
| LCP | G | Graphical Loc. Cont. Panel | 
| Coating PCB | C | Coated PCB | 
| Mains Option | X | No Mains Option | 
| Adaptation A | X | Standard Cable Entries | 
| Adaptation B | X | No adaptation | 
| Software Release | SXXX | Latest release std. SW. | 
| Software Language Pack | X | Standard Language Pack | 
| A Option | AL | PROFINET MCA 120 | 
| B Option | B2 | MCB-112 PTC Therm. Card | 
| C0 Option MCO | CX | No C0 option | 
| C1 Option | X | No C1 option | 
| C Option Software | XX | No software option | 
| D Option | D0 | MCB-107 24V DC backup | 
| Frame Size | C2 | C2 | 
| Typecode Part 1 | FC-202P90KT4E21H1TGC | |
| Typecode Part 2 | XXXSXXXXALB2CXXXXD0 | |
| Product Catalog | GLBL | Global (Standard) | 
| Power 150% (HO) [KW] | 75 | |
| Power 110% (NO) [KW] | 90 | |
| Height [mm] | 770,0 | |
| Width w/ no C options [mm] | 370,0 | |
| Depth [mm] | 335,0 | |
| Depth with Option A/B [mm] | 335,0 | |
| kVA | 123 | |
| Power Loss NO [W] | 1474 | |
| Power Loss NO [W] | 1474 | |
| Power Loss HO [W] | 1232 | |
| Power Loss HO [W] | 1232 | |
| Continuous Current (NO) [A] | 177 | |
| Intermittent Current (NO) [A] | 195 | |
| Continuous Current (NO) [A] | 160 | |
| Intermittent Current (NO) [A] | 176 | |
| Continuous Current (HO) [A] | 147 | |
| Intermittent Current (HO) [A] | 220 | |
| Continuous Current (HO) [A] | 130 | |
| Intermittent Current (HO) [A] | 195 | |
| Calculated Gross Weight [kg] | 56.2 | |
| Calculated Net Weight [kg] | 55.9 | |
| Plant from Orderline | B901 | |
| Vendor | ERR01 | Cannot Determine Vendor | 
| Recommended Factory | ERR01 | Cannot Determine Vendor | 
| Modelcode01 | FC-202P90KT4E21H1TGC | |
| Modelcode02 | XXXSXXXXALB2CXXXXD0 | 