Vacon Option modules:
The following option modules can be added to the Vacon series drives.
*Note that not all modules are compatible with all drive versions, please contact us for confirmation of compatibility.
Vacon 100 series general information about option boards |
|
| OPT-F3-V | Standard I/O board: 2 x AI, 6 x DI, 1 x AO, 10 Vref, 24 Vin, 2 x 24 Vout, RS485, 3 x RO |
| OPT-F4-V | Optional I/O board: 2 x AI, 6 x DI, 1 x AO, 10 Vref, 24 Vin, 2 x 24 Vout, RS485,2 x RO, Thermistor input |
| OPT-B1-V | 6 x DI / DO, programmable |
| OPT-B2-V | 2 x RO, Thermistor input |
| OPT-B4-V | 1 x AI, 2 x AO (isolated) |
| OPT-B5-V | 3 x RO |
| OPT-B9-V | 1 x RO, 5 x DI (42-240 VAC) |
| OPT-BF-V | 1 x AO, 1 x DO, 1 x RO |
| OPT-BH-V | 3 x Temp sensor inputs (PT100, PT1000, KTY84-130, TY84-150, KTY84-131, NI1000) |
| OPT-C4-V | LonWorks |
| OPT-E3-V | PROFIBUS DPV1 |
| OPT-E5-V | PROFIBUS DPV1 (D9) |
| OPT-E6-V | CANopen |
| OPT-E7-V | DeviceNet |
| OPT-EC-V | EtherCAT |
| OPT-BJ-V | Safe Torque Off (STO) / Safe Stop 1 (SS1) / ATEX |
|
Vacon NX options: |
|
Vacon NX series general information about option boards |
|
| OPT-A1 | Main board, 6 x DI, 1 x DO, 2 x AI, 1 x AO |
| OPT-A2 | Main board, 6 x DI |
| OPT-A3 | IO board, 1 x RO (NO/NC), 1 x TI (thermistor input) |
| OPT-A4 | 3 DI encoder (RS-422) + 2 DI (qualifier & fast input) |
| OPT-A5 | 3 DI encoder (wide range) + 2 DI (qualifier & fast input) |
| OPT-A7 | 6 DI encoder, 2 DO encoder |
| OPT-A8 | IO board, 6 x DI, 1 x DO, 2 x AI, 1 x AO |
| OPT-AE | 3 DI encoder (wide range), 2 DO (Enc.) |
| OPT-AK | Sin-Cos option board |
| OPT-AL | Six 42…240 VAC digital inputs, 2 analog inputs,two analog outputs, one digital output and 15 and 24 V out. |
| OPT-AN | IO board, 6 x DI, 2 x AI, 2, AO |
| OPT-B1 | IO board, 6 x DI, 6 x DO |
| OPT-B2 | IO board, 1 x TI (thermistor input), 2 x RO |
| OPT-B4 | IO board, 1 x AI (isolated), 2 x AO (isolated) |
| OPT-B5 | IO board, 3 x RO |
| OPT-B8 | 3 x Pt-100 |
| OPT-B9 | IO board, 1 x RO, 5 x 42-240VAC inputs |
| OPT-BC | Resolver |
| OPT-BE | Endat/SSI option board |
| OPT-BH | Temp measurement board – PT100, PT1000, NI1000, KTY84-130, KTY84-150, KTY84-131 |
| OPT-BB | Absolute encoder board – Endat type encoder |
| OPT-BJ | STO and ATEX option board |
| OPT-C2 | RS-485 (Multiprotocol) |
| OPT-C3 | Profibus DP |
| OPT-C4 | LonWorks |
| OPT-C5 | Profibus DP (D9-type connector) |
| OPT-C6 | CANopen (slave) |
| OPT-C7 | DeviceNet |
| OPT-C8 | RS-485 (Multiprotocol, D9-type connector) |
| OPT-CG | SELMA 2 protocol |
| OPT-CI | Modbus/TCP (Ethernet) |
| OPT-CJ | BACNet, RS485 |
| OPT-CP | ProfiNet I/O (Ethernet) |
| OPT-CQ | Ethernet/IP (Ethernet) |
| OPT-D1 | System Bus adapter (2 x fiber optic pairs) |
| OPT-D2 | System Bus adapter (1 x fiber optic pair) & CAN-bus adapter (galvanically decoupled) |
| OPT-D3 | RS232 adapter card (galvanically decoupled), used mainly for application engineering to connect another keypad |
| OPT-D6 | CAN-bus adapter (galvanically decoupled) |